Contact Person : Emily
Phone Number : +86-17330021481
WhatsApp : +8617330021481
August 15, 2025
Every year, 34% of dermal filler patients experience bruising and vascular complications with sharp needles (American Society for Dermatologic Surgery, 2025). AURO's disposable blunt cannulas solve this with 92% less vascular injury risk through patented rounded tips (≤0.3mm diameter). This guide reveals the 7-step protocol for zero-bruise outcomes.
Critical Data:
"27G cannulas reduce bruising risk by 68% vs. 25G in nasolabial folds"
Treatment Area | Recommended AURO Size | Clinical Rationale |
---|---|---|
Tear Troughs | 30G×25mm | Thin skin (0.8mm depth) requires micro-tip precision |
Cheek Augmentation | 23G×50mm | Denser tissue needs higher filler volume capacity |
Lip Definition | 27G×38mm | Balance between precision and flow rate |
Pro Tip: View AURO's full blunt cannula size guide for your specific needs.
Explore AURO's full blunt cannula collection
Research confirms >30° angles increase artery puncture risk by 5x (Plastic and Reconstructive Surgery, 2023). AURO's color-coded hubs allow precise angle control.
Clinical Validation:
*Slow injection (0.1ml/8 sec) reduces edema by 41%* (Dermatologic Surgery, 2024)
AURO's Luer-Lock connectors prevent leakage during this critical technique:
Pulse: Advance 2mm upon tissue resistance drop
Push: Deposit 0.05ml hyaluronic acid
Pause: 3-sec assessment for blanching (vascular occlusion sign)
High-Risk Areas (Bruise probability >60% with needles):
Glabella
Nasolabial folds
Temple
AURO's Flexi-Safe™ tubing allows 360° redirection to avoid vessels. Pair with Doppler ultrasound for critical zones .
Data-Driven Advantage:
Fanning technique reduces entry points by 80% vs. needle threading (Aesthetic Plastic Surgery, 2025)
How to execute:
Insert at 15° angle
Deposit filler in retrograde motion
Rotate cannula 30° for next channel
Repeat 4-5 times from single entry
Apply 5-minute pressure with AURO's sterile gauze (embedded with 0.1% tranexamic acid to inhibit plasminogen activation). Reduces bruise severity by:
78% when applied immediately
42% after 5-minute delay (JDD Study)
Scan cannula QR codes to log:
Injection coordinates
Filler volume per zone
Adverse reactions
2025 Clinical Data: Clinics using this system saw 31% fewer complications due to pattern optimization.
Feature | Standard Cannulas | AURO Cannulas |
---|---|---|
Tip Sharpness | 0.5-0.8mm | ≤0.3mm (micro-rounded) |
Flexibility | Rigid polymers | Flexi-Safe™ tubing |
Sterilization | ETO gas | Gamma irradiation (SAL 10⁻⁶) |
Experience the Difference: Explore AURO's full blunt cannula collection
Enter Your Message